<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Cisco B200 M3 blades &#8211; AgileOps</title>
	<atom:link href="https://agileops.co.uk/category/cisco-b200-m3-blades/feed/" rel="self" type="application/rss+xml" />
	<link>https://agileops.co.uk</link>
	<description>Virtualization made simple for Everyone.</description>
	<lastBuildDate>Tue, 26 May 2020 15:02:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.8</generator>

<image>
	<url>https://agileops.co.uk/wp-content/uploads/2017/10/favicon-01-50x50.png</url>
	<title>Cisco B200 M3 blades &#8211; AgileOps</title>
	<link>https://agileops.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">194680508</site>	<item>
		<title>UCS Blade unable to ping or connect to vCenter</title>
		<link>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/</link>
					<comments>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/#comments</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Fri, 31 Oct 2014 22:30:11 +0000</pubDate>
				<category><![CDATA[Cisco B200 M3 blades]]></category>
		<category><![CDATA[Cisco Boot Flash]]></category>
		<category><![CDATA[Cisco FlexFlash]]></category>
		<category><![CDATA[CISCO UCS]]></category>
		<category><![CDATA[CISCO UCS Firmware Upgrade]]></category>
		<category><![CDATA[Cisco UCS FlexFlash]]></category>
		<category><![CDATA[Cisco UCS M3 Blades]]></category>
		<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[cisco ucs server]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[ucs manger]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[duplicate ip address]]></category>
		<category><![CDATA[duplicate mac]]></category>
		<category><![CDATA[esxcfg-nics -l]]></category>
		<category><![CDATA[esxcfg-vmknic]]></category>
		<category><![CDATA[network connectivity issue]]></category>
		<category><![CDATA[ucs blade not responding on network]]></category>
		<category><![CDATA[UCS Blade unable to ping or connect to vCenter]]></category>
		<category><![CDATA[vmknic mac]]></category>
		<category><![CDATA[vnic mac]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=913</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
				<![CDATA[<script async src="//pagead2.googlesyndication.com/pagead/js/adsbygoogle.js"></script>
<script>
  (adsbygoogle = window.adsbygoogle || []).push({
    google_ad_client: "ca-pub-9905384192895993",
    enable_page_level_ads: true
  });
</script>

Hi All,

I came across a strange issue where 2 blades was unable to ping I could get 2 ping and then Request time outs

<strong>Problem :</strong> 2 Servers( in the same chassis server 3,4 ) unable to ping their gateway. Ping drops are after 1-2 packets. We cannot ping/ssh to them from outside and they cannot be added to vCenter. Other blades in the same chassis are working ( 1,2)

<strong>Steps Taken :</strong>


<ol>
	

<li>Confirmed that we do not have any IP conflicts</li>


	

<li>Made sure that we do not use the same subnet anywhere else in the network</li>


	

<li>Also checked and confirmed that the Mgmt(CIMC) subnet is different</li>


</ol>


<a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/ucs1-1.png"><img fetchpriority="high" decoding="async" class="size-full wp-image-923" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/ucs1-1.png" alt="ucs1" width="604" height="160" /></a>


<ol>
	

<li>Started a ping from inside a Host ( Server-3 ) to check if you are able to get to the gateway</li>


	

<li>Checked vobd logs  to find if you can find any  entrie <span style="font-size:13px;">for duplicate ip/mac</span></li>


	

<li>Checked the Mgmt Interface : vmk0</li>


	

<li>It is connected to Port Group : Management Network  on VLAN ID, Check if we are  using the right vlan</li>


	

<li>Found that the MAC Address of the vmk0 is same as vnic (vmnic0) : This is a known issue VMware KB article <a title="Duplicate MAC addresses" href="https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111" target="_blank">here</a>. This is the vnic mac address of the service profile which is attached to the esx blade.</li>


	

<li>Deleted and re-created the vmk0 interface</li>


	

<li>Confirmed that the MAC Address has changed</li>


	

<li>Started a continuous ping which work fine now</li>


	

<li>Host can now be added to the vCenter</li>


</ol>


&nbsp;

&nbsp;

So let me go through of the process of how we found the duplicate mac address.

The vnic mac address was taken by vmknic  as you might know vmknic mad starts with 00:50:56 but in my case it was same as the mac address of vnic from the service profile.<span id="more-913"></span>

login to the host and give the command

<em><strong>#esxcfg-nics -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/esxcfg-nics1-1.png"><img decoding="async" class="alignright wp-image-925 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/esxcfg-nics1-1.png" alt="" width="984" height="54" /></a></p>


this gives the list of vnics assigned to the service profile, note the management nics in my case vnic 0 and 1

then give the below command to get the vmkernal nics

<em><strong>#esxcfg-vmknic -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p11-1.png"><img decoding="async" class="alignright wp-image-915 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p11-1.png" alt="" width="1027" height="78" /></a></p>


as you can see above the mac address is not starting from 00:50:56 and it is been duplicated from the vnic template from the service profile vnic0 which is the root cause for the connectivity issue.

Now to fix this we have to delete the virtual switch and re-create it.

<em><strong>#esxcfg-vswitch -l</strong></em>

This lists the virtual switches


<p style="text-align:justify;"><img loading="lazy" decoding="async" class="wp-image-920 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p21-1.png" alt="" width="649" height="152" /></p>


#esxcfg-vmknic -d -p &#8216;Management Network&#8217;

you have to specify exact name of the port

Now we will need to add the vmknic with the same Management network

<em><strong>#esxcfg-vmknic -a -i &lt;IPaddress&gt; -n &lt;Netmask&gt; &#8216;Management Network&#8217; </strong></em>

and also give the command <em><strong>#esxcfg-vswitch -l</strong></em>  to check the Management network created as shown below.

note you can not give a gateway at this point you can specify frm DCA


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p3-1.png"><img loading="lazy" decoding="async" class="size-full wp-image-918" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p3-1.png" alt="p3" width="604" height="124" /></a></p>


 you should now be able to ping to the host as it has got a new mac address to check it you can give the command

<em><strong>#esxcfg-vmknic -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p34-1.png"><img loading="lazy" decoding="async" class="size-full wp-image-922" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p34-1.png" alt="p34" width="604" height="53" /></a></p>


&nbsp;

for a continus ping you can give

#ping &lt;gateway ip&gt; -c 100

this will give 100 continuous pings

&nbsp;

Reference:

<a href="https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111">https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111</a>]]&gt;		</div>
<p><!-- .vgblk-rw-wrapper --></p>
]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">913</post-id>	</item>
		<item>
		<title>Cisco UCS FlexFlash Configuration of Secure Digital (SD) Card</title>
		<link>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/</link>
					<comments>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/#comments</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Thu, 21 Aug 2014 19:32:54 +0000</pubDate>
				<category><![CDATA[Cisco B200 M3 blades]]></category>
		<category><![CDATA[Cisco Boot Flash]]></category>
		<category><![CDATA[Cisco FlexFlash]]></category>
		<category><![CDATA[CISCO UCS]]></category>
		<category><![CDATA[Cisco UCS FlexFlash]]></category>
		<category><![CDATA[Cisco UCS M3 Blades]]></category>
		<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[M3 Blades]]></category>
		<category><![CDATA[mirroring sd card]]></category>
		<category><![CDATA[raid sd card]]></category>
		<category><![CDATA[sd card]]></category>
		<category><![CDATA[SD Card Mirroring]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Windows SQL Server EXPRESS]]></category>
		<category><![CDATA[B200 M3 Server]]></category>
		<category><![CDATA[Cisco FlexFlash: Use and Manage February 2014 Cisco Flexible Flash Internal SD Card for Cisco UCS]]></category>
		<category><![CDATA[Cisco SD Card configuration]]></category>
		<category><![CDATA[Cisco SD card Mirroing]]></category>
		<category><![CDATA[cisco ucs]]></category>
		<category><![CDATA[CISCO UCS B200 Blade]]></category>
		<category><![CDATA[Cisco UCS New firmware]]></category>
		<category><![CDATA[FlexFlash]]></category>
		<category><![CDATA[M3 blades]]></category>
		<category><![CDATA[Raid 1]]></category>
		<category><![CDATA[SD Card]]></category>
		<category><![CDATA[ucs]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=767</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper"><![CDATA[

<h1]]&gt;
<p>Cisco UCS FlexFlash /SDCard Configuration for Booting Server Operating System. As most of the Cisco UCS users might be aware that Cisco has now add a lot of improvements and new features on the latest upgrade 2.2(1e). One of the feature which we have started using is Cisco FlexFlash which is an SD Card. Its fully support if you buy the SD  Card from Cisco and we can even do mirroring on the Flash cards for redundancy, we will be installing ESXi Server 5.5 on these blades after mirroring them. So where and How to install the Secure Digital (SD) Card  ? If the CISCO UCS B200 Blade is in the Chassis you will need to power it off and slide it out just half way through and you should find the SD Card slot on the left   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/cisco-ucs-sdcard-slot-1.png?w=266" alt="cisco ucs sdcard slot" width="401" height="252" /> for more information on how about this can be found on the following link https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M3.html As you might be aware that CISCO UCS blade is just as equal to a brick and all the configuration is done on the logical server called Service profile. you will need to create a new  / clone an existing Service profile template and modify with the below changes which I have shown below on this post. You will have to create a boot policy with CD Drive (legacy ) and SD Card and Some time you may end up getting this error &#8216; <a href="https://quraishi.wordpress.com/2014/09/19/advanced-boot-or-secure-boot-configuration-cannot-be-applied-to-the-specified-server-there-are-not-enough-resources-overall/" rel="bookmark">advanced boot or secure boot configuration cannot be applied to the specified server There are not enough resources overall</a> &#8216; if you see it follow my blog post. I have to make you aware that if you want to use SD card with Mirroring or RAID 1 you have to create the following new policies and create a Boot policy as mentioned above. 1. Disk policy with Mirror and any configuration <img loading="lazy" decoding="async" class=" wp-image-789 alignleft" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/raid_policy-1.jpg" alt="Raid_policy" width="468" height="452" />                               2.   We have to create two Scrub policy under policy ( you can call it any thing you want which makes you understand what configuration you have selected)</p>
<ol>
<li>Flex Flash Scrub</li>
<li>No Scrub</li>
</ol>
<p>So where will you find the Flex Flash Controller? Click on the Left pan on Equipment and Select the Chassis then the Server, on the right you will find the below details click on Inventory and select the last tab which is Storage on the Storage tab you will find FlexFlash Controller <em>Note: this FlexFlash is only support if you are running 2.2 (d1) firmware.</em> <span id="more-767"></span>   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflashsettings-1.jpg?w=266" alt="FlexFlashsettings" width="435" height="404" /> Once you assign the new service profile policy, we will see the below error on the FlexFlaash Cards <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enablepaired-invalied-secondary-1.png?w=184" alt="EnablePaired Invalied Secondary" width="358" height="517" /></p>
<ol start="2">
<li>Go to the service Profile and select the Policies and change the Scrub policy</li>
<li> in this create 2 policy the default is no scrub but you can create one called FlexFlash Scrub and the  other one No Scrub</li>
</ol>
<p>To create the scrub policy click on Service profile of the server and click <strong>Policy &gt; Scrub </strong>and click <strong>Create Scrub Policy</strong> <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/how-to-create-scrub-policy-1.png?w=266" alt="how to create scrub policy" width="447" height="284" /></p>
<ol start="2">
<li>You will have to use the first policy for Flex flash Scrub which should have the below settings.</li>
</ol>
<p>FlexFlash Scrub: should set to Yes   <img loading="lazy" decoding="async" class="wp-image-792 alignleft" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflash-scrub-1.png" alt="FlexFlash-Scrub" width="493" height="240" /></p>
<ol start="3">
<li>You then need to create a new policy for No-Scrub as shown below :</li>
</ol>
<p><img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/no-scrub-1.png?w=266" alt="No-Scrub" width="495" height="240" /> After creating two policy this is the tricky bit to have the SD card as  Mirror you will need to do two reboots first set the scrub policy to FlexFlash-Scrub ( note this will scrub the SD cards)  and click Save   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflash-scrubpolicychange-1.png?w=266" alt="FlexFlash-Scrubpolicychange" width="536" height="415" /> Do the following steps:</p>
<ol start="3">
<li>Go to the server and Click server Maintenance this will scrub the flash</li>
<li>Reboot the server  in the following manor, go the the Equipment tab select the Chassis and the server Click on &#8216;<em>Server Maintenance&#8217;</em> and click on &#8216;<em>Re-acknowledge&#8217;</em> server</li>
</ol>
<p><img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/reack_servers-1.png?w=225" alt="reack_servers" width="368" height="435" /> Acknowledge for Reboot <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/ack_reboot-1.png?w=266" alt="ack_reboot" width="354" height="137" /> You will find the rediscovery <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/server_rebooting-1.png?w=266" alt="server_rebooting" width="315" height="289" /> Once its configured go back to service profile Go to &gt; Polices Select Scrub Policy and change it to No-Scrub from the drop down menue   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/change-scrub-policy-1.png?w=266" alt="change-scrub-policy" width="266" height="92" />   which should look like below:   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/change-the-scrub-to-no-1.png?w=266" alt="Change the scrub to No" width="400" height="257" />   5. Go to the server and Click server Maintenance this will Mirror and pair the SD card to Raid1/ Mirroring 6. Reboot the server  in the following manor, go the the Equipment tab select the Chassis and the server Click on &#8216;<em>Server Maintenance&#8217;</em> and click on &#8216;<em>Re-acknowledge&#8217;</em> server Acknowledge for Reboot   After the server does the  rediscovery and boots successfully, You will see that this is successfully paired with is RAID 1 Mirroring. Please note the <strong>Raid Status : Enabled Paired</strong>   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enabled-pair1-1.png?w=266" alt="Enabled-Pair" width="477" height="409" /> Error message if the Raid is not working, this means you have to go through the process again. always make sure you only change the scrub policy on the specific server profile and not the service profile template as this will create problems on the working profiles. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enablepaired-invalied-secondary-1.png?w=184" alt="EnablePaired Invalied Secondary" width="477" height="689" /> Another example of error is Raid Status Disabled <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflashunhealthy_raid-1.png?w=181" alt="FlexFlashUnhealthy_RAID" width="463" height="681" />   <strong>How to test ?</strong> The only confirmation we can get is on the below image where it says Raid Status <strong>Enabled Paired, </strong>however I have tested swapping the SD cards out one by one and the ESXi  Server boots successfully you will immediately see the error message that the pair is disabled. Unfortunately you will need to pull the server out to change swap the SD cards but hay at least you will find out if the mirroring is working. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enabled-pair1-1.png?w=266" alt="Enabled-Pair" width="428" height="367" />     Also you will need to remember that after installing ESXi on SD card will give you an error message on the ESXi host that  &#8216;The ESXi host does not have persistent storage&#8217;  you will need to add the storage and  a scrach partition. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/persistant-disk-1.png?w=266" alt="persistant-disk" width="489" height="79" /> To create a scrach partition follow the below VMware KB. https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1033696 o<del>r I might create a blog on how to do it later&#8230;</del> My friend Vikram has just posted the process on his blog www.viktec.com <a title="Permanent Link to System logs on host are stored on non-persistent storage" href="https://viktec.wordpress.com/2014/09/11/system-logs-on-host-are-stored-on-non-persistent-storage/" rel="bookmark">System logs on host are stored on non-persistent storage</a> Please find the new updates the latest firmware is bringing.  Release 2.2(1b) adds support for the following: IPv6 Management Support Cisco Integrated Management Controller (CIMC) In-band Management Fabric scaling: VLAN, VIFs, IGMP, Network Adapter Endpoints Uni-Directional Link Detection (UDLD) Support User Space NIC (usNIC) for Low Latency Support for Virtual Machine Queue (VMQ) C-Series Servers Direct Connect to FI without FEX Two-factor Authentication for UCS Manager Logins VM-FEX for Hyper-V Management with Microsoft SCVMM Direct KVM Access Server Firmware Auto Sync Enhanced Local Storage Management Flash Adapters and HDD Firmware Management Precision Boot Order Control Secure Boot UEFI Boot Support FlexFlash (Local SD card) Support Trusted Platform Module (TPM) Inventory DIMM Blacklisting and Correctable Error Reporting C-Series Board Controller Firmware Management   Additional resources related to this post:   If you want to learn more about the process of doing a Firmware update please checkout my link <a href="https://quraishi.wordpress.com/2014/09/02/cisco-ucs-firmware-update-process/" rel="bookmark">CISCO UCS Firmware Update Process</a> If you want to learn more about the process of doing a Firmware update please checkout my link <a href="https://quraishi.wordpress.com/2014/09/19/advanced-boot-or-secure-boot-configuration-cannot-be-applied-to-the-specified-server-there-are-not-enough-resources-overall/" rel="bookmark">advanced boot or secure boot configuration cannot be applied to the specified server There are not enough resources overall </a></div>
<p><!-- .vgblk-rw-wrapper --></p>
]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/feed/</wfw:commentRss>
			<slash:comments>5</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">767</post-id>	</item>