<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>cisco ucs sd card &#8211; AgileOps</title>
	<atom:link href="https://agileops.co.uk/category/cisco-ucs-sd-card/feed/" rel="self" type="application/rss+xml" />
	<link>https://agileops.co.uk</link>
	<description>Virtualization made simple for Everyone.</description>
	<lastBuildDate>Tue, 26 May 2020 15:02:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.5.8</generator>

<image>
	<url>https://agileops.co.uk/wp-content/uploads/2017/10/favicon-01-50x50.png</url>
	<title>cisco ucs sd card &#8211; AgileOps</title>
	<link>https://agileops.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">194680508</site>	<item>
		<title>Troubleshooting The vMotion migration failed because the ESX host were not able to connect over the vMotion network.</title>
		<link>https://agileops.co.uk/troubleshooting-the-vmotion-migration-failed-error/</link>
					<comments>https://agileops.co.uk/troubleshooting-the-vmotion-migration-failed-error/#comments</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Mon, 10 Nov 2014 22:02:26 +0000</pubDate>
				<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[cisco ucs server]]></category>
		<category><![CDATA[CISCO UCS Unified Computing System]]></category>
		<category><![CDATA[Hardware Virtualization]]></category>
		<category><![CDATA[Hosted Virtualization]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[VCenter]]></category>
		<category><![CDATA[vCenter Server]]></category>
		<category><![CDATA[virtualized]]></category>
		<category><![CDATA[vMotion]]></category>
		<category><![CDATA[VMware]]></category>
		<category><![CDATA[Vmware]]></category>
		<category><![CDATA[Cisco Systems Inc]]></category>
		<category><![CDATA[dvport]]></category>
		<category><![CDATA[esxcfg]]></category>
		<category><![CDATA[esxcfg-nics]]></category>
		<category><![CDATA[esxcfg-nics -l]]></category>
		<category><![CDATA[esxcfg-vmknic]]></category>
		<category><![CDATA[esxcfg-vmknic -l]]></category>
		<category><![CDATA[migration]]></category>
		<category><![CDATA[service profile]]></category>
		<category><![CDATA[Troubleshooting]]></category>
		<category><![CDATA[ucs]]></category>
		<category><![CDATA[vmkping]]></category>
		<category><![CDATA[vmotion]]></category>
		<category><![CDATA[vMotion migration failed Troubleshooting]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=883</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper"><p>Hi All,</p>
<p>Today I will take you thought the troubleshooting for vMotion using CLI, If you have not done network troubleshooting on esx host you will find some really good esxi commands on this post. And if you are using a converged infrastructure its important to understand end to end connectivity especially if you have different vlans for each service like vMotion FT, Management traffic and VM-Traffic.</p>
<p>I build a brand new Data Center and after configuring the dv switch I decided to test the vMotion first and this is the error I saw on the first attempt the vm was stuck at 14 % and after a while it gave the below error message.</p>
<p>as shown below:</p>
<p><a href="https://quraishi.files.wordpress.com/2014/10/vmotion-error_task.png"><img decoding="async" class="size-full wp-image-886" src="https://quraishi.files.wordpress.com/2014/10/vmotion-error_task.png" alt="vmotion error_task" width="604" height="55" /></a></p>
<p> </p>
<p>Migrate virtual machine error message</p>
<p style="text-align: justify;"><a href="https://quraishi.files.wordpress.com/2014/10/vmotion-error.png"><img fetchpriority="high" decoding="async" class="size-full wp-image-885" src="https://quraishi.files.wordpress.com/2014/10/vmotion-error.png" alt="vmotion error" width="604" height="181" /></a></p>
<p>If you read the above error message you will find the IP&#8217;s of the host which I am migrating from and to.</p>
<p>for example lets consider the below two host this troubleshooting is done on esx-02. vmnic2 is FT vmnic3 is vMotion so I am comparing the mac address of booth the host on the ucs service profile to compare tht the vnic template has the right mac address and if they are connected to the right vlan.<span id="more-883"></span></p>
<p><em>esx-01</em></p>
<p><em>vmnic2 0000:08:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:0d 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</em><br /><em> vmnic3 0000:09:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:0c 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</em></p>
<p><em> esx-02</em></p>
<p><em><span style="font-size: 13px;">vmnic2 0000:08:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:19 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</span></em></p>
<p><em> vmnic3 0000:09:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:18 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</em></p>
<ol>
<li>check the mac address on ucs and on the esx host for the vmnic2 ( ft) vmnic3 (vmotion)</li>
<li>check the mtu it should be 9000 although this shuld not affect but I have changed them from 1500 mtu to 9000 mtu.</li>
<li> check the nics with mac address<br /><span style="color: #ff9900;">esxcfg-nics -l</span></li>
<li> check the vmkernal nics<br /><span style="color: #ff9900;">esxcfg-vmknic -l</span></li>
<li> ping from the vnic using<br /># <span style="color: #ff9900;">vmkping -I vmk2 192.168.242.1</span> this is using vmk2 interface which is for vmotion<br />you will notice its failing initially because the uplink on the dv switch was first given to both the ft and vmotion nics<br />I then moved the dvuplink_1 to unused as I and it was my mistake which is why it was not working agian.</li>
<li><span style="color: #ff9900;"> vmkping -I vmk2 192.168.242.1</span> the ping test failed again<br />then I moved the dvuplink_1 in active and moved dvuplink_2 to unused and the result is</li>
</ol>
<p>The time and date of this login have been sent to the system logs.</p>
<p>VMware offers supported, powerful system administration tools. Please<br />see www.vmware.com/go/sysadmintools for details.<!--more--></p>
<p>The ESXi Shell can be disabled by an administrative user. See the<br />vSphere Security documentation for more information.<br />~ # esxcfg-nics<br />esxcfg-nics &lt;options&gt; [nic]<br />-s|&#8211;speed &lt;speed&gt; Set the speed of this NIC to one of 10/100/1000/10000.<br />Requires a NIC parameter.<br />-d|&#8211;duplex &lt;duplex&gt; Set the duplex of this NIC to one of &#8216;full&#8217; or &#8216;half&#8217;.<br />Requires a NIC parameter.<br />-a|&#8211;auto Set speed and duplexity automatically. Requires a NIC parameter.<br />-l|&#8211;list Print the list of NICs and their settings.<br />-r|&#8211;restore Restore the nics configured speed/duplex settings (INTERNAL ONLY)<br />-h|&#8211;help Display this message.</p>
<p><a href="https://quraishi.files.wordpress.com/2014/10/cli.png"><img decoding="async" class="size-full wp-image-888" src="https://quraishi.files.wordpress.com/2014/10/cli.png" alt="cli" width="604" height="268" /></a></p>
<p style="text-align: justify;"> </p>
<p><strong><span style="color: #ff9900;">~ # esxcfg-nics -l</span></strong><br />Name PCI Driver Link Speed Duplex MAC Address MTU Description<br />vmnic0 0000:06:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:14 1500 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic1 0000:07:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:1a 1500 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic10 0000:10:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:10 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic11 0000:11:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:11 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br /><span style="color: #ff0000;">vmnic12 0000:12:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:0f 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</span><br /><span style="color: #ff0000;"> vmnic13 0000:13:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:10 9000 Cisco Systems Inc Cisco VIC Ethernet NIC</span><br />vmnic14 0000:14:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:0c 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic15 0000:15:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:0f 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic2 0000:08:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:19 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic3 0000:09:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:18 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic4 0000:0a:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:13 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic5 0000:0b:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:17 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic6 0000:0c:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:12 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic7 0000:0d:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:16 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic8 0000:0e:00.00 enic Up 20000Mbps Full xx:xx:xx:a3:01:11 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br />vmnic9 0000:0f:00.00 enic Up 20000Mbps Full xx:xx:xx:b3:01:15 9000 Cisco Systems Inc Cisco VIC Ethernet NIC<br /><strong><span style="color: #ff9900;">~ # esxcfg-vmknic -l</span></strong><br />Interface Port Group/DVPort IP Family IP Address Netmask Broadcast MAC Address MTU TSO MSS Enabled Type<br />vmk0 Management Network IPv4 192.168.248.2 255.255.254.0 192.168.249.255 xx:xx:xx:a3:01:14 1500 65535 true STATIC<br /><span style="color: #ff0000;">vmk1 1 IPv4 192.168.240.2 255.255.254.0 192.168.241.255 xx:xx:xx:68:7c:e3 9000 65535 true STATIC</span><br />vmk3 1 IPv4 192.168.237.2 255.255.255.0 192.168.237.255 xx:xx:xx:67:0d:34 1500 65535 true STATIC<br />vmk4 1 IPv4 192.168.245.2 255.255.255.0 192.168.245.255 xx:xx:xx:68:07:a0 1500 65535 true STATIC<br />vmk5 1 IPv4 192.168.244.2 255.255.255.0 192.168.244.255 xx:xx:xx:62:60:66 1500 65535 true STATIC<br />vmk6 129 IPv4 192.168.245.102 255.255.255.0 192.168.245.255 xx:xx:xx:64:9c:a8 1500 65535 true STATIC<br />vmk7 129 IPv4 192.168.244.102 255.255.255.0 192.168.244.255 xx:xx:xx:65:b6:41 1500 65535 true STATIC<br /><span style="color: #ff0000;">vmk2 129 IPv4 192.168.242.2 255.255.254.0 192.168.243.255 xx:xx:xx:65:ff:87 9000 65535 true STATIC</span></p>
<p><span style="color: #ff9900;">~<strong> # vmkping -I vmk2 192.168.242.1 &#8211;  [ping to the esx-01 failed]</strong></span><br />PING 192.168.242.1 (192.168.242.1): 56 data bytes</p>
<p>&#8212; 192.168.242.1 ping statistics &#8212;<br />3 packets transmitted, 0 packets received, 100% packet loss<br /><strong><span style="color: #ff9900;">~ # vmkping -I vmk2 192.168.242.2   &#8211; [ this is the same host I am troubleshooting so its ping is ok.]</span></strong><br />PING 192.168.242.2 (192.168.242.2): 56 data bytes<br />64 bytes from 192.168.242.2: icmp_seq=0 ttl=64 time=0.081 ms<br />64 bytes from 192.168.242.2: icmp_seq=1 ttl=64 time=0.027 ms<br />64 bytes from 192.168.242.2: icmp_seq=2 ttl=64 time=0.055 ms</p>
<p>&#8212; 192.168.242.2 ping statistics &#8212;<br />3 packets transmitted, 3 packets received, 0% packet loss<br />round-trip min/avg/max = 0.027/0.054/0.081 ms<br />~ #<br />~<strong><span style="color: #ff9900;"> # vmkping -I </span><span style="color: #ff0000;">vmk1</span><span style="color: #ff9900;"> 192.168.242.2 [  vmk1 is the vmkernal port of FaultTolarant so it will not ping as its on a different subnet and vlan]</span></strong><br />PING 192.168.242.2 (192.168.242.2): 56 data bytes</p>
<p>&#8212; 192.168.242.2 ping statistics &#8212;<br />2 packets transmitted, 0 packets received, 100% packet loss</p>
<p><strong><span style="color: #ff9900;">~ # vmkping -I vmk1 192.168.240.2</span></strong><br />PING 192.168.240.2 (192.168.240.2): 56 data bytes<br />64 bytes from 192.168.240.2: icmp_seq=0 ttl=64 time=0.084 ms</p>
<p>&#8212; 192.168.240.2 ping statistics &#8212;<br />2 packets transmitted, 2 packets received, 0% packet loss<br />round-trip min/avg/max = 0.039/0.062/0.084 ms<br />~ # vmkping -I vmk1 192.168.240.1<br />PING 192.168.240.1 (192.168.240.1): 56 data bytes</p>
<p>&#8212; 192.168.240.1 ping statistics &#8212;<br />2 packets transmitted, 0 packets received, 100% packet loss</p>
<p>Now it is clear that the MAC and NIC are presented correct from UCS service profile and we have verified the MAC address and pinging from the vmkernal ports proofs that its is still not working.</p>
<p>I have check that they vnic template is connected to the right vlan on ucs. So next thing I have done is check the dvport group and I found that I had two uplinks on active which was wrong as one uplink is only for FT which has vlan 20and the other uplink is for vMotion which is on 21 vlan.</p>
<p>So, I have moved the dvuplink2 to unused as its for FT. on the dvport group which is for vMotion as shown below:</p>
<p><a href="https://quraishi.files.wordpress.com/2014/10/dv_switch.png"><img loading="lazy" decoding="async" class="size-full wp-image-889" src="https://quraishi.files.wordpress.com/2014/10/dv_switch.png" alt="dv_switch" width="604" height="445" /></a></p>
<p>&#8212; 192.168.242.2 ping statistics &#8212;</p>
<p>3 packets transmitted, 3 packets received, 0% packet loss<br />round-trip min/avg/max = 0.040/0.061/0.088 ms<br /><strong><span style="color: #ff9900;">~ # vmkping -I vmk2 192.168.242.1</span></strong><br /><span style="color: #99cc00;">PING 192.168.242.1 (192.168.242.1): 56 data bytes</span><br /><span style="color: #99cc00;"> 64 bytes from 192.168.242.1: icmp_seq=0 ttl=64 time=0.428 ms</span><br /><span style="color: #99cc00;"> 64 bytes from 192.168.242.1: icmp_seq=1 ttl=64 time=0.197 ms</span><br /><span style="color: #99cc00;"> 64 bytes from 192.168.242.1: icmp_seq=2 ttl=64 time=0.219 ms</span></p>
<p><span style="color: #99cc00;">&#8212; 192.168.242.1 ping statistics &#8212;</span></p>
<p><a href="https://quraishi.files.wordpress.com/2014/10/successful_migration1.png"><img loading="lazy" decoding="async" class="size-full wp-image-892" src="https://quraishi.files.wordpress.com/2014/10/successful_migration1.png" alt="successful_migration" width="604" height="20" /></a><br />3 packets transmitted, 3 packets received, 0% packet loss<br />round-trip min/avg/max = 0.197/0.281/0.428 ms</p>


<p></p>
</div><!-- .vgblk-rw-wrapper -->]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/troubleshooting-the-vmotion-migration-failed-error/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">883</post-id>	</item>
		<item>
		<title>UCS Blade unable to ping or connect to vCenter</title>
		<link>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/</link>
					<comments>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/#comments</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Fri, 31 Oct 2014 22:30:11 +0000</pubDate>
				<category><![CDATA[Cisco B200 M3 blades]]></category>
		<category><![CDATA[Cisco Boot Flash]]></category>
		<category><![CDATA[Cisco FlexFlash]]></category>
		<category><![CDATA[CISCO UCS]]></category>
		<category><![CDATA[CISCO UCS Firmware Upgrade]]></category>
		<category><![CDATA[Cisco UCS FlexFlash]]></category>
		<category><![CDATA[Cisco UCS M3 Blades]]></category>
		<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[cisco ucs server]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[ucs manger]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[duplicate ip address]]></category>
		<category><![CDATA[duplicate mac]]></category>
		<category><![CDATA[esxcfg-nics -l]]></category>
		<category><![CDATA[esxcfg-vmknic]]></category>
		<category><![CDATA[network connectivity issue]]></category>
		<category><![CDATA[ucs blade not responding on network]]></category>
		<category><![CDATA[UCS Blade unable to ping or connect to vCenter]]></category>
		<category><![CDATA[vmknic mac]]></category>
		<category><![CDATA[vnic mac]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=913</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
				<![CDATA[<script async src="//pagead2.googlesyndication.com/pagead/js/adsbygoogle.js"></script>
<script>
  (adsbygoogle = window.adsbygoogle || []).push({
    google_ad_client: "ca-pub-9905384192895993",
    enable_page_level_ads: true
  });
</script>

Hi All,

I came across a strange issue where 2 blades was unable to ping I could get 2 ping and then Request time outs

<strong>Problem :</strong> 2 Servers( in the same chassis server 3,4 ) unable to ping their gateway. Ping drops are after 1-2 packets. We cannot ping/ssh to them from outside and they cannot be added to vCenter. Other blades in the same chassis are working ( 1,2)

<strong>Steps Taken :</strong>


<ol>
	

<li>Confirmed that we do not have any IP conflicts</li>


	

<li>Made sure that we do not use the same subnet anywhere else in the network</li>


	

<li>Also checked and confirmed that the Mgmt(CIMC) subnet is different</li>


</ol>


<a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/ucs1-1.png"><img loading="lazy" decoding="async" class="size-full wp-image-923" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/ucs1-1.png" alt="ucs1" width="604" height="160" /></a>


<ol>
	

<li>Started a ping from inside a Host ( Server-3 ) to check if you are able to get to the gateway</li>


	

<li>Checked vobd logs  to find if you can find any  entrie <span style="font-size:13px;">for duplicate ip/mac</span></li>


	

<li>Checked the Mgmt Interface : vmk0</li>


	

<li>It is connected to Port Group : Management Network  on VLAN ID, Check if we are  using the right vlan</li>


	

<li>Found that the MAC Address of the vmk0 is same as vnic (vmnic0) : This is a known issue VMware KB article <a title="Duplicate MAC addresses" href="https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111" target="_blank">here</a>. This is the vnic mac address of the service profile which is attached to the esx blade.</li>


	

<li>Deleted and re-created the vmk0 interface</li>


	

<li>Confirmed that the MAC Address has changed</li>


	

<li>Started a continuous ping which work fine now</li>


	

<li>Host can now be added to the vCenter</li>


</ol>


&nbsp;

&nbsp;

So let me go through of the process of how we found the duplicate mac address.

The vnic mac address was taken by vmknic  as you might know vmknic mad starts with 00:50:56 but in my case it was same as the mac address of vnic from the service profile.<span id="more-913"></span>

login to the host and give the command

<em><strong>#esxcfg-nics -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/esxcfg-nics1-1.png"><img loading="lazy" decoding="async" class="alignright wp-image-925 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/esxcfg-nics1-1.png" alt="" width="984" height="54" /></a></p>


this gives the list of vnics assigned to the service profile, note the management nics in my case vnic 0 and 1

then give the below command to get the vmkernal nics

<em><strong>#esxcfg-vmknic -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p11-1.png"><img loading="lazy" decoding="async" class="alignright wp-image-915 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p11-1.png" alt="" width="1027" height="78" /></a></p>


as you can see above the mac address is not starting from 00:50:56 and it is been duplicated from the vnic template from the service profile vnic0 which is the root cause for the connectivity issue.

Now to fix this we have to delete the virtual switch and re-create it.

<em><strong>#esxcfg-vswitch -l</strong></em>

This lists the virtual switches


<p style="text-align:justify;"><img loading="lazy" decoding="async" class="wp-image-920 size-full" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p21-1.png" alt="" width="649" height="152" /></p>


#esxcfg-vmknic -d -p &#8216;Management Network&#8217;

you have to specify exact name of the port

Now we will need to add the vmknic with the same Management network

<em><strong>#esxcfg-vmknic -a -i &lt;IPaddress&gt; -n &lt;Netmask&gt; &#8216;Management Network&#8217; </strong></em>

and also give the command <em><strong>#esxcfg-vswitch -l</strong></em>  to check the Management network created as shown below.

note you can not give a gateway at this point you can specify frm DCA


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p3-1.png"><img loading="lazy" decoding="async" class="size-full wp-image-918" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p3-1.png" alt="p3" width="604" height="124" /></a></p>


 you should now be able to ping to the host as it has got a new mac address to check it you can give the command

<em><strong>#esxcfg-vmknic -l</strong></em>


<p style="text-align:justify;"><a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p34-1.png"><img loading="lazy" decoding="async" class="size-full wp-image-922" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/10/p34-1.png" alt="p34" width="604" height="53" /></a></p>


&nbsp;

for a continus ping you can give

#ping &lt;gateway ip&gt; -c 100

this will give 100 continuous pings

&nbsp;

Reference:

<a href="https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111">https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1031111</a>]]&gt;		</div>
<p><!-- .vgblk-rw-wrapper --></p>
]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/ucs-blade-unable-to-ping-or-connect-to-vcenter/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">913</post-id>	</item>
		<item>
		<title>Cisco UCS Firmware Overview</title>
		<link>https://agileops.co.uk/cisco-ucs-firmware-overview/</link>
					<comments>https://agileops.co.uk/cisco-ucs-firmware-overview/#respond</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Wed, 03 Sep 2014 20:50:01 +0000</pubDate>
				<category><![CDATA[CISCO UCS]]></category>
		<category><![CDATA[CISCO UCS Firmware Upgrade]]></category>
		<category><![CDATA[Cisco UCS FlexFlash]]></category>
		<category><![CDATA[Cisco UCS M3 Blades]]></category>
		<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[CISCO UCS Unified Computing System]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[CISCO]]></category>
		<category><![CDATA[Cisco UCS Firmware Process]]></category>
		<category><![CDATA[Cisco UCS Firmware Update]]></category>
		<category><![CDATA[Firmware]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=819</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper">
				<![CDATA[Hello Everyone,

Cisco has recently launched a lot of  Firmware for CISCO UCS, it is becoming rather hard to keep up with the new release. We had 5 New Release in Version 2.2 starting from 2.2.(1b),  2.2.(1c), 2.2.(1d),  2.2.(1e), 2.2.(2c).

The good thing is, in every release CISCO  is adding some good features. In one of  the release 2.2.(1d) they have introduced boot from SD, FlexFlash, this option was not available on the older versions of  UCS Manager.

If you are intreasted in this, and want to find how you can boot the ESXi or any other OS off the Secure Digital (SD)  FlexFlash  and how this can be implemented do check  my post  here: <a href="https://quraishi.wordpress.com/2014/08/21/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/" rel="bookmark">Cisco UCS FlexFlash Configuration of Secure Digital (SD) Card</a>

So, for the newbee  to Cisco UCS,  its confusing about the firmware. In this post I am trying to clarify few aspects of this, feel free to post comment below if you have any questions and I will get back to you.

The CISCO UCS firmware is bundled into two packages as given below:

<a href="httpss://ibrahimquraishi.com/wp-content/uploads/2014/09/ucs_firmware-1.png"><img loading="lazy" decoding="async" class="alignright size-full wp-image-820" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/09/ucs_firmware-1.png" alt="ucs_firmware" width="604" height="284" /></a>

&nbsp;

<strong>1. Infrastructure Firmware</strong>

In Infrastructure Software firmware we update the firmware of the following


<ul>
	

<li>Cisco UCS Manager software</li>


	

<li> Kernel and system firmware for the fabric interconnects</li>


	

<li> I/O module firmware</li>


</ul>


<strong>2. Server Firmware</strong>

Cisco UCS <strong>B-Series Blade Server</strong> Software Bundle


<ul>
	

<li>CIMC firmware</li>


	

<li>BIOS firmware</li>


	

<li>Adapter firmware</li>


	

<li>Board controller firmware</li>


	

<li>Third-party firmware images required by the new server</li>


</ul>


<em><span class="uicontrol">This also includes the firmware of Adapter, </span>BIOS<span class="uicontrol">, </span>FC Adapters,  <span class="uicontrol">HBA Option ROM, </span>Storage, Controller, Local Disk</em>

Cisco UCS <strong>C-Series Rack-Mount UCS-Managed Server</strong> Software


<ul>
	

<li>CIMC firmware</li>


	

<li>BIOS firmware</li>


	

<li>Adapter firmware</li>


	

<li>Board controller firmware</li>


	

<li>Third-party firmware images required by the new server</li>


</ul>


As most of you might be aware the UCS manager is the GUI Java based which allows you to fully manage the CISCO Unified Computing System.

<em>Note I have noticed that the Java version  7 update 40 is only compatible with the UCS Manager. </em>

So, where does the UCS Manager run ?

This was one of my first questions, Well the Software of the UCS Manager runs on the FI ( Fabric Interconnect 62xx) as we have a pair of Fabric Interconnect it has got resilience.

The UCS System is designed to be highly scalable and available, so upgrading the firmware should not bring any outage to the environment. However Cisco still suggests to arrange a Change windows and get this done out of hours or the quite period of your business.

This UCS Manager is bundled in the Infrastructure Firmware Software along with the Kernal update of the FI which is the NXOS, Finally we have the I/O Module firmware which is a part of the Infrastructure firmware software too.

The Other Bundle is the Server Firmware which has the firmware for BIOS, the Blades, Adapter, Board controller etc.

If you want to learn more about the process of doing a Firmware update please checkout my link <a href="https://quraishi.wordpress.com/2014/09/02/cisco-ucs-firmware-update-process/" rel="bookmark">CISCO UCS Firmware Update Process</a>

Hope this information is useful, feel free to comment.]]&gt;		</div>
<p><!-- .vgblk-rw-wrapper --></p>
]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/cisco-ucs-firmware-overview/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">819</post-id>	</item>
		<item>
		<title>Cisco UCS FlexFlash Configuration of Secure Digital (SD) Card</title>
		<link>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/</link>
					<comments>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/#comments</comments>
		
		<dc:creator><![CDATA[Ibrahim Quraishi]]></dc:creator>
		<pubDate>Thu, 21 Aug 2014 19:32:54 +0000</pubDate>
				<category><![CDATA[Cisco B200 M3 blades]]></category>
		<category><![CDATA[Cisco Boot Flash]]></category>
		<category><![CDATA[Cisco FlexFlash]]></category>
		<category><![CDATA[CISCO UCS]]></category>
		<category><![CDATA[Cisco UCS FlexFlash]]></category>
		<category><![CDATA[Cisco UCS M3 Blades]]></category>
		<category><![CDATA[cisco ucs sd card]]></category>
		<category><![CDATA[M3 Blades]]></category>
		<category><![CDATA[mirroring sd card]]></category>
		<category><![CDATA[raid sd card]]></category>
		<category><![CDATA[sd card]]></category>
		<category><![CDATA[SD Card Mirroring]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Windows SQL Server EXPRESS]]></category>
		<category><![CDATA[B200 M3 Server]]></category>
		<category><![CDATA[Cisco FlexFlash: Use and Manage February 2014 Cisco Flexible Flash Internal SD Card for Cisco UCS]]></category>
		<category><![CDATA[Cisco SD Card configuration]]></category>
		<category><![CDATA[Cisco SD card Mirroing]]></category>
		<category><![CDATA[cisco ucs]]></category>
		<category><![CDATA[CISCO UCS B200 Blade]]></category>
		<category><![CDATA[Cisco UCS New firmware]]></category>
		<category><![CDATA[FlexFlash]]></category>
		<category><![CDATA[M3 blades]]></category>
		<category><![CDATA[Raid 1]]></category>
		<category><![CDATA[SD Card]]></category>
		<category><![CDATA[ucs]]></category>
		<guid isPermaLink="false">https://quraishi.wordpress.com/?p=767</guid>

					<description><![CDATA[
				<![CDATA[]]>		]]></description>
										<content:encoded><![CDATA[<div class="vgblk-rw-wrapper limit-wrapper"><![CDATA[

<h1]]&gt;
<p>Cisco UCS FlexFlash /SDCard Configuration for Booting Server Operating System. As most of the Cisco UCS users might be aware that Cisco has now add a lot of improvements and new features on the latest upgrade 2.2(1e). One of the feature which we have started using is Cisco FlexFlash which is an SD Card. Its fully support if you buy the SD  Card from Cisco and we can even do mirroring on the Flash cards for redundancy, we will be installing ESXi Server 5.5 on these blades after mirroring them. So where and How to install the Secure Digital (SD) Card  ? If the CISCO UCS B200 Blade is in the Chassis you will need to power it off and slide it out just half way through and you should find the SD Card slot on the left   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/cisco-ucs-sdcard-slot-1.png?w=266" alt="cisco ucs sdcard slot" width="401" height="252" /> for more information on how about this can be found on the following link https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/blade-servers/B200M3.html As you might be aware that CISCO UCS blade is just as equal to a brick and all the configuration is done on the logical server called Service profile. you will need to create a new  / clone an existing Service profile template and modify with the below changes which I have shown below on this post. You will have to create a boot policy with CD Drive (legacy ) and SD Card and Some time you may end up getting this error &#8216; <a href="https://quraishi.wordpress.com/2014/09/19/advanced-boot-or-secure-boot-configuration-cannot-be-applied-to-the-specified-server-there-are-not-enough-resources-overall/" rel="bookmark">advanced boot or secure boot configuration cannot be applied to the specified server There are not enough resources overall</a> &#8216; if you see it follow my blog post. I have to make you aware that if you want to use SD card with Mirroring or RAID 1 you have to create the following new policies and create a Boot policy as mentioned above. 1. Disk policy with Mirror and any configuration <img loading="lazy" decoding="async" class=" wp-image-789 alignleft" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/raid_policy-1.jpg" alt="Raid_policy" width="468" height="452" />                               2.   We have to create two Scrub policy under policy ( you can call it any thing you want which makes you understand what configuration you have selected)</p>
<ol>
<li>Flex Flash Scrub</li>
<li>No Scrub</li>
</ol>
<p>So where will you find the Flex Flash Controller? Click on the Left pan on Equipment and Select the Chassis then the Server, on the right you will find the below details click on Inventory and select the last tab which is Storage on the Storage tab you will find FlexFlash Controller <em>Note: this FlexFlash is only support if you are running 2.2 (d1) firmware.</em> <span id="more-767"></span>   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflashsettings-1.jpg?w=266" alt="FlexFlashsettings" width="435" height="404" /> Once you assign the new service profile policy, we will see the below error on the FlexFlaash Cards <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enablepaired-invalied-secondary-1.png?w=184" alt="EnablePaired Invalied Secondary" width="358" height="517" /></p>
<ol start="2">
<li>Go to the service Profile and select the Policies and change the Scrub policy</li>
<li> in this create 2 policy the default is no scrub but you can create one called FlexFlash Scrub and the  other one No Scrub</li>
</ol>
<p>To create the scrub policy click on Service profile of the server and click <strong>Policy &gt; Scrub </strong>and click <strong>Create Scrub Policy</strong> <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/how-to-create-scrub-policy-1.png?w=266" alt="how to create scrub policy" width="447" height="284" /></p>
<ol start="2">
<li>You will have to use the first policy for Flex flash Scrub which should have the below settings.</li>
</ol>
<p>FlexFlash Scrub: should set to Yes   <img loading="lazy" decoding="async" class="wp-image-792 alignleft" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflash-scrub-1.png" alt="FlexFlash-Scrub" width="493" height="240" /></p>
<ol start="3">
<li>You then need to create a new policy for No-Scrub as shown below :</li>
</ol>
<p><img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/no-scrub-1.png?w=266" alt="No-Scrub" width="495" height="240" /> After creating two policy this is the tricky bit to have the SD card as  Mirror you will need to do two reboots first set the scrub policy to FlexFlash-Scrub ( note this will scrub the SD cards)  and click Save   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflash-scrubpolicychange-1.png?w=266" alt="FlexFlash-Scrubpolicychange" width="536" height="415" /> Do the following steps:</p>
<ol start="3">
<li>Go to the server and Click server Maintenance this will scrub the flash</li>
<li>Reboot the server  in the following manor, go the the Equipment tab select the Chassis and the server Click on &#8216;<em>Server Maintenance&#8217;</em> and click on &#8216;<em>Re-acknowledge&#8217;</em> server</li>
</ol>
<p><img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/reack_servers-1.png?w=225" alt="reack_servers" width="368" height="435" /> Acknowledge for Reboot <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/ack_reboot-1.png?w=266" alt="ack_reboot" width="354" height="137" /> You will find the rediscovery <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/server_rebooting-1.png?w=266" alt="server_rebooting" width="315" height="289" /> Once its configured go back to service profile Go to &gt; Polices Select Scrub Policy and change it to No-Scrub from the drop down menue   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/change-scrub-policy-1.png?w=266" alt="change-scrub-policy" width="266" height="92" />   which should look like below:   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/change-the-scrub-to-no-1.png?w=266" alt="Change the scrub to No" width="400" height="257" />   5. Go to the server and Click server Maintenance this will Mirror and pair the SD card to Raid1/ Mirroring 6. Reboot the server  in the following manor, go the the Equipment tab select the Chassis and the server Click on &#8216;<em>Server Maintenance&#8217;</em> and click on &#8216;<em>Re-acknowledge&#8217;</em> server Acknowledge for Reboot   After the server does the  rediscovery and boots successfully, You will see that this is successfully paired with is RAID 1 Mirroring. Please note the <strong>Raid Status : Enabled Paired</strong>   <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enabled-pair1-1.png?w=266" alt="Enabled-Pair" width="477" height="409" /> Error message if the Raid is not working, this means you have to go through the process again. always make sure you only change the scrub policy on the specific server profile and not the service profile template as this will create problems on the working profiles. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enablepaired-invalied-secondary-1.png?w=184" alt="EnablePaired Invalied Secondary" width="477" height="689" /> Another example of error is Raid Status Disabled <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/flexflashunhealthy_raid-1.png?w=181" alt="FlexFlashUnhealthy_RAID" width="463" height="681" />   <strong>How to test ?</strong> The only confirmation we can get is on the below image where it says Raid Status <strong>Enabled Paired, </strong>however I have tested swapping the SD cards out one by one and the ESXi  Server boots successfully you will immediately see the error message that the pair is disabled. Unfortunately you will need to pull the server out to change swap the SD cards but hay at least you will find out if the mirroring is working. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/enabled-pair1-1.png?w=266" alt="Enabled-Pair" width="428" height="367" />     Also you will need to remember that after installing ESXi on SD card will give you an error message on the ESXi host that  &#8216;The ESXi host does not have persistent storage&#8217;  you will need to add the storage and  a scrach partition. <img loading="lazy" decoding="async" class="attachment-266x266" src="httpss://ibrahimquraishi.com/wp-content/uploads/2014/08/persistant-disk-1.png?w=266" alt="persistant-disk" width="489" height="79" /> To create a scrach partition follow the below VMware KB. https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&amp;cmd=displayKC&amp;externalId=1033696 o<del>r I might create a blog on how to do it later&#8230;</del> My friend Vikram has just posted the process on his blog www.viktec.com <a title="Permanent Link to System logs on host are stored on non-persistent storage" href="https://viktec.wordpress.com/2014/09/11/system-logs-on-host-are-stored-on-non-persistent-storage/" rel="bookmark">System logs on host are stored on non-persistent storage</a> Please find the new updates the latest firmware is bringing.  Release 2.2(1b) adds support for the following: IPv6 Management Support Cisco Integrated Management Controller (CIMC) In-band Management Fabric scaling: VLAN, VIFs, IGMP, Network Adapter Endpoints Uni-Directional Link Detection (UDLD) Support User Space NIC (usNIC) for Low Latency Support for Virtual Machine Queue (VMQ) C-Series Servers Direct Connect to FI without FEX Two-factor Authentication for UCS Manager Logins VM-FEX for Hyper-V Management with Microsoft SCVMM Direct KVM Access Server Firmware Auto Sync Enhanced Local Storage Management Flash Adapters and HDD Firmware Management Precision Boot Order Control Secure Boot UEFI Boot Support FlexFlash (Local SD card) Support Trusted Platform Module (TPM) Inventory DIMM Blacklisting and Correctable Error Reporting C-Series Board Controller Firmware Management   Additional resources related to this post:   If you want to learn more about the process of doing a Firmware update please checkout my link <a href="https://quraishi.wordpress.com/2014/09/02/cisco-ucs-firmware-update-process/" rel="bookmark">CISCO UCS Firmware Update Process</a> If you want to learn more about the process of doing a Firmware update please checkout my link <a href="https://quraishi.wordpress.com/2014/09/19/advanced-boot-or-secure-boot-configuration-cannot-be-applied-to-the-specified-server-there-are-not-enough-resources-overall/" rel="bookmark">advanced boot or secure boot configuration cannot be applied to the specified server There are not enough resources overall </a></div>
<p><!-- .vgblk-rw-wrapper --></p>
]]></content:encoded>
					
					<wfw:commentRss>https://agileops.co.uk/cisco-ucs-flexflash-configuration-of-secure-digital-sd-card/feed/</wfw:commentRss>
			<slash:comments>5</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">767</post-id>	</item>
	</channel>
</rss>